Авторизация

Чтобы совершать покупки на нашем сайте, необходимо войти на него под своим логином и паролем.

Введите пароль

Забыли пароль?

Если у вас еще нет учетной записи, необходимо зарегистрироваться

×
Каталог

Каталог

QIAcube Connect

For fully automated nucleic acid extraction with QIAGEN spin-column kits

  • Automates over 80 QIAGEN kits with over 3000 protocols
  • Allows automated DNA, RNA and protein sample processing
  • Eliminates manual processing steps
  • Generates standardized results 
  • Enables quick response times and remote run monitoring through the provided tablet

QIAcube Connect is the next generation of the widely used QIAcube, and is redefining the benefits of automating sample processing. With advanced digital capabilities and connectivity that builds on the success of QIAcube, QIAcube Connect allows research labs to fully automate and track their well known QIAGEN spin-column extraction and purification protocols – at the push of a button.

QIAcube Connect offers an augmented user interface that provides a new dimension of utility. Researchers can stay connected to their instrument through the built-in screen and also remotely with a tablet (included), containing the pre-installed QIAcube Connect App, enabling quick response times and ability to monitor runs while away from the QIAcube Connect.

QIAcube Connect operates in conjunction with QIAcube Connect Accessories.

Артикул: 9002844
QIAcube Connect System
Robotic workstation for automated purification of DNA, RNA or proteins using QIAGEN spin-column kits: includes tablet and Q-Base to connect to local network, bar code reader, a preventive subscription for one year that includes one on-site preventive inspection service and 1-year warranty on parts and labor
Артикул: 9002843
QIAcube Connect Priority Plus
Robotic workstation for automated purification of DNA, RNA or proteins using QIAGEN spin-column kits: includes tablet and Q-Base to connect to local network, bar code reader, installation, introductory training, 3-year warranty on parts and labor and 3 preventive inspection services
Артикул: 9002842
QIAcube Connect Priority
Robotic workstation for automated purification of DNA, RNA, or proteins using QIAGEN spin-column kits: includes tablet and Q-Base to connect to local network, bar code reader, installation, introductory training, 2-year warranty on parts and labor and two preventive inspection services
Артикул: 9002840
QIAcube Connect
Robotic workstation for automated purification of DNA, RNA or proteins using QIAGEN spin-column kits: includes tablet and Q-Base to connect to local network, bar code reader and 1-year warranty on parts and labor


Performance

The revolutionary QIAcube Connect makes automated sample prep available to all laboratories. The plug-and-play instrument simplifies and streamlines your purification procedures by fully automating the trusted QIAGEN spin-column kits. No change of chemistry is required, assuring fast startup and immediate results, and performance is comparable to the manual procedure. The innovative QIAcube Connect enables you to free up your valuable time, continue to use proven QIAGEN spin-column kits, standardize your results and increase your productivity. 

Principle

The QIAcube Connect enables continued use of well-established QIAGEN spin-column kits and eliminates the need for tedious manual steps. The innovative QIAcube Connect controls integrated components including a centrifuge, heated shaker, pipetting system and robotic gripper. This enables the QIAcube Connect to fully automate more than 80 QIAGEN spin column kits.

UV light decontamination

You can now achieve convenient and efficient full worktable decontamination with the new built-in UV light of the QIAcube Connect. By making use of the UV light decontamination feature of our enhanced instrument, you can prevent any carryover between samples, allowing for a single instrument to purify DNA, RNA, pathogen nucleic acids and proteins from a vast array of sample types barely detectable after UV light exposure).

Remote connectivity

With the new QIAcube Connect you can now spend less time preparing your sample prep run and waiting around for your results, and more time thinking about your research! That’s because the new QIAcube Connect comes with a tablet that allows for easier sample prep run preparation, and provides you with status updates on the progress of your run.

Furthermore, the QIAcube Connect comes with a barcode scanner. Simply scan the barcode of your sample prep kit, and all the necessary kit information will immediately appear on your screen.

Illuminated worktable

The QIAcube Connect is provided with a light inside the instrument, making it easier to load your samples and perform your experiments.

Protocols for various sample types

The QIAcube Connect is provided with a variety of pre-installed protocols for purification of RNA, genomic DNA, plasmid DNA, viral nucleic acids and proteins, plus DNA and RNA cleanup. All standard protocols in the expanding range can also be downloaded free of charge. Customized protocols tailored to meet your specific application demands can also be requested.

Procedure

The QIAcube Connect enables purification of highly pure nucleic acids or proteins using a simple lysis, bind, wash and elute procedure.

Unparalleled ease-of-use

With the QIAcube Connect, ease-of-use is taken to a new level. A large integrated touchscreen (see figure ''The QIAcube Connect touchscreen'') simplifies protocol selection, and clear on-screen messages guide the user through worktable setup. For increased ease-of-use and high process safety, labware and accessories fit onto the worktable only in the correct orientation. In addition, a fully automated load check helps to ensure that samples, reagents and labware are loaded correctly.

Dedicated kits for DNA and RNA preps

Dedicated QIAcube Connect kits further simplify automated spin-preps on the QIAcube Connect, and increase convenience. Kits are currently available for purification of RNA, genomic DNA and viral RNA. Rotor-adapters supplied with the kits are pre-loaded with spin columns and elution tubes, delivering greater convenience and saving time. Furthermore, ease-of-use is increased, user errors are minimized and waste is reduced, as the content of the dedicated kits is tailored to purification on the QIAcube Connect, and tubes required for the manual procedure are not included.

Applications

The QIAcube Connect is highly suitable for academic research laboratories as well as pharmaceutical, biotechnology, and biomedical research laboratories performing applications, such as:

  • Sequencing/sequencing analysis
  • Gene expression analysis
  • Genotyping
  • Proteomics 
  • Microbiome research

Features
Specifications
Altitude Up to 2000 m (6500 ft.)
Centrifuge 10,640 rpm maximum, 12,000 x g maximum, swing-out rotor maximum 45°, 12 rotor positions
Data output USB stick: USB2.0; Compatible OS: Windows 8, Windows 7, Windows Vista, Windows XP (SP3 or later); Mac OS x 10,1 or later; Operating temperature range: 0?C to 35?C; Operating humidity range: 10 to 90% (with no condensation); Storage temperature range: –20?C to 60?C (–4?F to 140?F); Storage humidity range: 10 to 90% (with no condensation); Formatting: FAT32
Environmental class 3K2 (IEC 60721-3-3)
Instrument dimensions Dimensions (hood closed): width 65 cm (25.6 in.), height 58 cm (22.8 in.), depth 62 cm (24.4 in.); Dimensions (hood open): width 65 cm (25.6 in.), height 86 cm (34 in.), depth 62 cm (24.4 in.); Mass: QIAcube Connect: 71.5 kg (157.6 lb.); Accessories: 3 kg (6.6 lb.)
Operating temperature 18 to 28?C (64.4 to 82.4?F)
Pipetting system Syringe size 1 ml, pipetting range 5–900 µl
Place of operation For indoor use only
Pollution level 2
Relative humidity 15–75% (non-condensing)
Shaker Speed 100–2000 rpm, amplitude 2 mm, heating range of ambient temperature to 70°C (158°F), ramp-up time of
Software QIAGEN protocols are preinstalled on the QIAcube Connect.
Special feature Handheld scanner; Scan pattern: Area Image (838 x 640-pixel array); Motion tolerance: Up to 610 cm/s (240 in/s) for 13 mil UPC at optimal focus; Symbol contrast: 20% minimum reflectance difference; Decode capability: Reads standard 1D, PDF, 2D, Postal and OCR symbology
Storage conditions Temperature: 15?C to 30?C (59?F to 86?F) in manufacturer’s package; Relative humidity: Max. 75% (non-condensing); Environmental class: 1K2 (IEC 60721-3-1)
Table capacity Up to 12 samples per run
Technical data Power: 100–240 V AC, 50/60 Hz, 650 VA Mains supply voltage fluctuations are not to exceed 10% of nominal supply voltages. Note: The apparent power can exceed 650 VA for up to 2 seconds during the centrifuge acceleration and can reach an approximate value of 1000 VA.; Fuse: 2x T6.3A L 250V; Overvoltage category: II
Touchscreen 10.4” TFT Touchscreen, active area 211.2 x 158.4 mm, resolution 800*600 SVGA
Transportation conditions –25°C to 60°C (–13°F to 140°F) in manufacturer's package; Max. 75% relative humidity (non-condensing); Environmenal class: 2K2 (IEC 60721-3-2)
UV lamp Wavelength: 278 nm; Optical power: 200-300 mW